WoFu Fire & Security Equipment Co., Ltd.

Fire Prevention, Fire Detection, Fire System manufacturer / supplier in China, offering Hfc-227ea Gas Fire Protection System, 2-Wire Conventional Fire Bell, Sys Automatic Water Pressure Test Machine 400kg, Fire Fighting Equipment, Voltage 220V and so on.

Hfc-227ea Gas Fire Protection System

FOB Price: Get Latest Price
Min. Order: 1 Set
Port: Guangzhou, China
Production Capacity: 20000bottle /Set Per Month
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request

Basic Info.

Type:Fire Extinguisher System
Certification:CCC
Retirement Life:8 Years
Cylinder Color:Red
Storage Pressure:2.5/4.2MPa
Trademark:WELFARE
Transport Package:Wooden Case
Specification:40L/70L/100L/120L/150L/180L
Origin:China (Mainland)
HS Code:842410000

Product Description

HFC-227ea gas fire protection system

1. System Introduction

HFC-227ea is a clean extinguishing agent, which would completely vaporized in the air, and well
Insulated. Its total flooding mode is applicable to electric fire, liquid fire or fusible solid fire, solid
Surface fire, gas fire which gas supply is cut before extinguishing. And it is able to protect computer
Rooms, communication rooms, substation rooms, hi-tech device rooms, generator rooms, gasoline
Storerooms, combustible chemical storerooms, libraries, data rooms, archives, treasuries, etc. We
Manufacture HFC-227ea system that is well structured, reliable, and widely applied to computer
Rooms, archives, program control exchange engine rooms, TV broadcast center, financial
Organizations and government departments.

2 System Main Technical Parameter

2.1 Storage of cylinder: 40L/70L/100L/120L/150L/180L
2.2 Storage Pressure: 2.5MPa/4.2MPa(20º C)
2.3 Maximum Working Pressure (50º C): 3.4MPa/5.3MPa
2.4 Operating Method: Electromagnetic starter; Emergency mechanical starter
2.5 Nitrogen pressure of the electromagnetic driving device: 6.0± 1.0MPa (20º C)
2.6 Starter power of the electromagnetic driving device: DC24V/1.5A
2.7 Extinguishing agent filling density: ≤ 1150kg/m3
2.8 Extinguishing agent spurting time: ≤ 8s
2.9 Protective Area Temperature: 0º C~50º C
2.9 Cylinder spurting allowance: ≤ 2kg/bottle
2.10 Cylinder-room temperature requirement: -10º C~50º C
NameValve  sizeCylinder 
outsize (mm)
Cylinder weight(kg)Weight (cylinder
+valve+
hose)
Wooden case
size(mm)
20LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
1"260*550*41723900*300*400
40LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
5/4"260*950*430381280*310*400
70LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
5/4"300*1120*647561480*360*450
100LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
2"360*1190*666761550*410*500
106LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
2"400*1021*672821300*450*650
120LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
2"360*1400*668781800*410*500
150LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
2"410*1340*685941700*460*550
180LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
2"400*1634*6931312050*460*550
240LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
2"500*1400*81471631880*550*640
280LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
2"500*1590*81822002100*550*640
343LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
3"600*1466*102302591880*670*760
450LTR FM200 Cylinder+valve+solenoid valve
+gauge+diptube+high pressure flexible hose 
3"650*1520*123663981930*720*810
3.FM200 fire extinguishing system order instruction:
HFC-227ea Fire Suppression system is one of Special Design and Manufacture products .
Before we make offer, we need your detailed information support to calculate the qty of Cylinder, weight of gas ,pipe size, nozzle ...
if the system you requested need design or not ?we design them free charges ,
We need following information to make design for your engineer projected
1>,What's your protected subject :
Telecommunication Facilities________
Computer operations _______
Control rooms __________
Shipboard (marine )system ________
Rare book Libraries ____________
University and Museum _____________
Art Galleries _________________
Petrochemical installations _________
Medical Facilities and Pharmaceutical________
2>,do you have room 's layout or drawing
yes ( if yes please send us your attachment )
2. no (if no please tell us below protection status)
A room size : length(X width(m)X height ( m) (M)
B raise floor(can not greater than 30mm): _______(M ), or NO _____
C ceiling , height ____ (M) , or .no need consider
3>do you need a pressure release device ,yes .
4> storage cylinder must be placed in a separate room and towards the door opening direction
5> . HFC-227ea system select
A , Dependable system one system protect a single room(no need flow check valve)
B. Muliti-hazard system (One system protect multiple rooms(use selection valve)_________
6>.do you need fire alarm products ( control panel ,detectors , gas lamp ) yes no
7>.do you need pipe net yes no
8 >.do you need coupling and pipes yes . no
9>.do you need nozzle yes no
If nozzle requested please fill blew
Size: 1" 1.5" 2" 2.5"
Thread : Male female
Nozzle holes number-------PCS ,holes diameter ____mm
Send your message to this supplier
Avatar
Ms. Michelle Xue
Manager
*From
To Ms. Michelle Xue
*Message
Enter between 20 to 4,000 characters.
This is not what you are looking for? Post a Sourcing Request Now
Find Similar Products By Category:

WoFu Fire & Security Equipment Co., Ltd.

- Hunan, China
- Manufacturer/Factory, Trading Company

Gold Member Since 2007
Audited Supplier
  • Sample Available
  • OEM/ODM Service
  • Spanish Speaker