• Automatic High Pressure CO2 Clean Agent Fire Fighting System Design
  • Automatic High Pressure CO2 Clean Agent Fire Fighting System Design
  • Automatic High Pressure CO2 Clean Agent Fire Fighting System Design
  • Automatic High Pressure CO2 Clean Agent Fire Fighting System Design
  • Automatic High Pressure CO2 Clean Agent Fire Fighting System Design
  • Automatic High Pressure CO2 Clean Agent Fire Fighting System Design

Automatic High Pressure CO2 Clean Agent Fire Fighting System Design

Certification: CE
Fire Control Panel: One Zone
High Pressure Hose: Stailness Steel
Scale Device: Carbon Steel
Cylinder Size: 70LTR 45kg
Valve: Brass
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
70L
Gas One Way Valve
Brass
Pressure Switch
Brass
Detector
Intellegent Smoke Detector
Material
Carbon Steel Ck45
Nozzle
Total Flooding Nozzle
Transport Package
Wooden Case
Trademark
WELFARE
Origin
Guangdong, China (Mainland)

Product Description

Automatic co2 clean agent fire fighting system design

 

1.CO2 fire fighting system introduction:

The carbon dioxide is liquidized by high pressure and stored in cylinders, when spraying the 

carbon dioxide is expending sharply and absorbing a large quantity of heat, thus to reduce

the temperature of the fire scene and dilute the oxygen level of the protected zone so as to put 

the fire out. Carbon dioxide is a inert gas, which is inexpensive, non-polluted, dissipated, and 

traceless. The carbon dioxide fire extinguishing system is able to put gas fire out after the gas 

supply source is cut, and it is also able to put out liquid fire, solid fire of fusible materials such as paraffin and asphalt, solid surface fire, deep-seated solid fire such as wincey, fabric, 

and paper, and electric fire, etc. The system is applicable to libraries, archives, database, bulk storages of liquid, computer rooms, communication rooms, generator rooms, substation rooms, oil 

immersion slots, mechanical mills, drying devices, and lacquer product lines. Note that co2 causes asphyxiation and the system shall be used where no people are involved. If the system 

takes effect in working places appropriate measures shall be taken to ensure safety.

The system puts out fires in a sealed room in a total flooding mode , it also works in a local 

application mode to put out non deep-seated fire of protected objects where sealed rooms are 

not required. The local application mode uses special nozzles which allow the extinguishing agent 

acts fully on combustion object directly, the system keeps supplying extinguishing agent on the 

combustion object for a certain time and intensity in order to put out the fire.

 

2.System technical parameters:

 

1.Storage of cylinder:70L/45Kg

2.Storage pressure(20):5.7MPa

3.Max working pressure(50):14.4MPa

4.Driving mode:electromagnetic,emergency mechanical

5.Nitrogen pressure of the electromagnetic driving device6.0±1.0MPa (20)

6.Starter power of the electromagnetic driving device:  DC24V/1.5A

7.Extinguishing agent spraying time:≤60s

8.Protective area temperature:0~50

9.spraying leavings of cylinder:≤3Kg/bottle

10.Cylinder-room temperature requirement:0~50

 

3.CO2 Fire suppression system accessories:

 

Fire control panel syotistem, smoke/heat/phc detector system, alarm system(fire bell, manual call,video audio alarm),equipment, cylinder, valve, selective valve, liquid,che,preck pipessure switch, 

nozzle, pipe, ect.

Automatic High Pressure CO2 Clean Agent Fire Fighting System Design Automatic High Pressure CO2 Clean Agent Fire Fighting System Design Automatic High Pressure CO2 Clean Agent Fire Fighting System Design Automatic High Pressure CO2 Clean Agent Fire Fighting System Design

Automatic High Pressure CO2 Clean Agent Fire Fighting System Design

 

 

4.CO2 System order instruction:

You are still in troubling get complex offer?? Hope you meet three following situation

Case 1. If client can supply drawing layout .we can make free design and make offer to you within 24hours , pls send us your drawing room layout.

Case 2. If client has equipment list ?? pls contact us , we can make free design and make offer to you within 24hours

Case 3. No any drawing layout , no equipment list , then give us your room size : length Xwidth X height and door information

 

We will send the design drawing to you check before produce:

Automatic High Pressure CO2 Clean Agent Fire Fighting System Design

5.CO2 System package photos:

 

Use wooden case(non fumigation) to pack it,good protect products.

Automatic High Pressure CO2 Clean Agent Fire Fighting System Design

Automatic High Pressure CO2 Clean Agent Fire Fighting System Design

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now