• Hfc-227ea Clean Agent Fire Suppression System
  • Hfc-227ea Clean Agent Fire Suppression System
  • Hfc-227ea Clean Agent Fire Suppression System
  • Hfc-227ea Clean Agent Fire Suppression System
  • Hfc-227ea Clean Agent Fire Suppression System

Hfc-227ea Clean Agent Fire Suppression System

Agent: FM200
Type: Pipe Type
Object: Class Abce Fire
Size: 20~450L
Certification: CCC, GB50370-2005
Power Source: Pressure Fire Extinguisher
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
FM200
Fire Extinguishing Means
Total Flooding and Fully-Immersing
System Design Working Pressure
25bar 42bar 56bar
System Operation Max. Working Pressure
5.3mpa ~ 5.4mpa
Design Pressure of The Nozzle
Normal 0.7mpa, Min.0.40mpa
Single Nozzle Protection Radius
Less 5m
Single Nozzle Protective Height
Less 5m
Discharging Time
Less 10s
Gas Filling Rate( Density)
Less 1.15kg/L
Working Temperature
-10 to +60
System Start Ways
Automatic Control, Pneumatic Manual and Emergency
Transport Package
Wooden Case
Specification
20ltr, 40ltr, 70ltr, 90ltr, 100ltr, to 343ltr
Trademark
WELFARE
Origin
Guangzhou
HS Code
842410000
Production Capacity
2000bottle /Set Per Month

Product Description

From 1998, We Design, manufacture, installation, Operation and Maintenance HFC-227ea Fire Suppression System

Design According to the following Standard:
China GB795. GB79G, GB410, GB14104, NFPA-2001(U. S. A)
GA400-2002<<Testing Way and Performance of extinguishing system Parts >>
Inside Gas: UL EX6288 describled NFPA2001

Where to use:
Bank data room, gold house,
Painting lines
Generator room, motor room,
Switch board room
Transformer room
Computer and servor room
Communication room
Ware house
All the other place where can not put out the fire by water

Not suitable for extinguishing following fire
1. Oxidizing Chemical and mixture, such as
2. Activitly metal, such as potassium(K), magnesium(Mg), Zirconium( Zr), etc.
3. Metal hydroxide, Potassium hydride, Sodium hydride
4. Miscellaneous fire caused by decomposition Chemical, Such as Hydrogen oxide,

How the System Working:
Hfc-227ea Clean Agent Fire Suppression SystemGas storage cylinder; 20LTR, 30LTR, 40LTR, 60LTR, 70LTR, 100LTR, 120LTR, 150LTR, 180LTR, 250LTR, 343LTR,
Power Supply: DCV 24, 0.5A
Max Protective Area: 8 Zones (depend on designs)

Three Actuated ways:

Automatic Control
Electric Manual Control
Manual emergency control

System classification
Unit independent system 
Means one Fire Suppression system only can protect a protection area. I
Combination and distribute system
Means one fire Suppression system protected several protection area.
Three Part Production constructed whole System

All accessories:
Cylinder +valve +electrical solenoid + pressure gauge+High pressure discharge hose, connecting pipe, manifold pipe, Liquid or gas no Return valve, pressure switch, selection valve ( in multi protection system ), flange, elbow and nozzle

Working pressure: 4.2 Mpa or 2.5Mpa
Discharge time: ≤ 10s
Filling desity: ≤ 950kg/m3
Polit valve powder supply: 6.0± 1.0 Mpa(20C)
System working power: AC 220V DC 24V 1A
System working pressure: -10c~55C
Max protected area: Max 800m² , max volume 3600m³
Working means: Manual, auto, and eletrical
Capacity: 20L, 40L, 70L, 100L, 120L, 150L 180L, 240lLTR, 343LTR

Hfc-227ea Clean Agent Fire Suppression System
FIRE DETECTS AND ALARMS
Fire control panel +smoke and heat detectors
Fire alarm bell +manual button,
Light warning gas discharging
Hfc-227ea Clean Agent Fire Suppression System
Before we make offer we need follow technical

Room size: Length width height
Protected subject
Better submit drawing of project
We can send offer within 24 hours after received your informations.

This instruction base conditional Wofu present system, any renew without further Instruction,
Please contact Wofu for more details or newest technical...

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now