Clean Agent High Pressure CO2 Auto Fire Extinguishing System

Product Details
Customization: Available
Certification: CE
Fire Control Panel: One Zone
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
147802.18 USD
Type of Ownership
Limited Company
  • Clean Agent High Pressure CO2 Auto Fire Extinguishing System
  • Clean Agent High Pressure CO2 Auto Fire Extinguishing System
  • Clean Agent High Pressure CO2 Auto Fire Extinguishing System
  • Clean Agent High Pressure CO2 Auto Fire Extinguishing System
  • Clean Agent High Pressure CO2 Auto Fire Extinguishing System
  • Clean Agent High Pressure CO2 Auto Fire Extinguishing System
Find Similar Products

Basic Info.

Model NO.
FL-EZX-ZE70
Scale Device
Carbon Steel
Cylinder Size
70LTR 45kg
Valve
Brass
Gas One Way Valve
Brass
Pressure Switch
Brass
Detector
Intellegent Smoke Detector
Material
Carbon Steel Ck45
Nozzle
Total Flooding Nozzle
Transport Package
Wooden Case
Trademark
WELFARE
Origin
Zhejiang, China (Mainland)

Product Description

clean gas co2 fire extinguishing system

 

 

1.CO2 Fire extinguishing System Introduction:

 

The co2 is liquidized by high pressure and stored in cylinders, when spraying the 

carbon dioxide is expending sharply and absorbing a large quantity of heat, thus to reduce

the temperature of the fire scene and dilute the oxygen level of the protected zone so as to put 

the fire out. Carbon dioxide is a inert gas, which is inexpensive, non-polluted, dissipated, and 

traceless. The carbon dioxide fire extinguishing system is able to put gas fire out after the gas 

supply source is cut, and it is also able to put out liquid fire, solid fire of fusible materials 

such as paraffin and asphalt, solid surface fire, deep-seated solid fire such as wincey, fabric, 

and paper,and electric fire, etc. The system is applicable to libraries, archives, database, bulk 

storages of liquid, computer rooms, communication rooms, generator rooms, substation rooms, oil 

immersion slots, mechanical mills, drying devices, and lacquer product lines. Note that carbon 

dioxide causes asphyxiation and the system shall be used where no people are involved. If the 

system takes effect in working places appropriate measures shall be taken to ensure safety.

The system puts out fires in a sealed room in a total flooding mode , it also works in a local 

application mode to put out non deep-seated fire of protected objects where sealed rooms are 

not required. The local application mode uses special nozzles which allow the extinguishing agent 

acts fully on combustion object directly, the system keeps supplying extinguishing agent on the 

combustion object for a certain time and intensity in order to put out the fire.

 

2.CO2 Gas cylinder technical parameters:

 

Volume:70L;      Fire extinguishing agent:CO2                                             

Accessories: tank / valve/ internal siphon tube/flexible hose/gas check valve;                     Tank size:1500*267*5.7m(diameter*height*thickness);                                

Gas weight:45kg                                                      

Storage pressure(20):5.7MPa                                                

Max working pressure(50): 14.4MPa                                                    

Painting:  red epoxy polysteter/red coating polyster RAL3000;                                     

Valve size:brass,thread: PZ39, hose thread: G5/8, release pressure:19 ±0.95;

Container valve is consisted of valve body, starter device, piston, relief device, etc.             Extinguishing agent spraying time:≤60s;                               

Protective area temperature:0~50                                   

Spraying leavings of cylinder:≤3Kg/bottle

Clean Agent High Pressure CO2 Auto Fire Extinguishing System

3.CO2 Fire suppression system accessories:

 

Fire control panel syotistem, smoke/heat/phc detector system, alarm system(fire bell, manual call,video audio alarm),equipment, cylinder, valve, selective valve, liquid,che,preck pipessure switch,  

nozzle, pipe, ect.

Clean Agent High Pressure CO2 Auto Fire Extinguishing System

 

4.CO2 Fire suppression system packing pictures:

 

Use non fumigation wooden case to packing,good protect.

Clean Agent High Pressure CO2 Auto Fire Extinguishing System

Clean Agent High Pressure CO2 Auto Fire Extinguishing System

 

 

5.CO2 Fire suppression system order instruction:

 

How you can get our offer ??

You are still in troubling get complex offer ?? Hope you meet three following situation

Case 1, If client can supply drawing layout .we can make free design and make offer to you within 24hours, pls send us your drawing room layout.

Case 2. If client has equipment list ?? pls contact us, we can make free design and make offer to you within 24hours

Case 3. No any drawing layout, no equipment list, then give us your room size: length X width X height and door information

Clean Agent High Pressure CO2 Auto Fire Extinguishing System Clean Agent High Pressure CO2 Auto Fire Extinguishing System Clean Agent High Pressure CO2 Auto Fire Extinguishing System Clean Agent High Pressure CO2 Auto Fire Extinguishing System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.