New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system

Product Details
Customization: Available
Certification: CE
Agent Weight: 16.8kg
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
147802.18 USD
Type of Ownership
Limited Company
  • New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system
  • New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system
  • New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system
  • New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system
Find Similar Products

Basic Info.

Model NO.
IG541
Cylinder Size
80L
Extinguishing Agent
Mixed Gas Ig541
Transport Package
Wooden Case
Trademark
welfare
Origin
Guangdong, China (Mainland)

Product Description

Product Description

New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system

IG541 Fire suppression system parts

 

1.IG541 fire suppression system introduction:

 

Mixed gas IG541 is made up of 52% 40% 40% nitrogen, argon, carbon dioxide mixture of 

proportion by the steric (physical) way,in a short period of time after discharge to the protection 

zone can make protection zone of the oxygen concentration is reduced to support combustion 

under 12.5%, and burning fire smothering action implementation, on the other hand, according tothe long-term medical experiments prove that the human body in 12.5% oxygen concentration 

and the concentration of 2% to 5% carbon dioxide environment breath, brain of oxygen and 

at normal atmospheric environment (21% oxygen concentration and co2 concentration 0.03%) 

gained by the oxygen content is the same. This is because in hypoxia environment, if carbon 

dioxide concentrations increased to 2% 5% can make people breathing deepen and accelerate, 

in unit time make the person obtains enough oxygen to brain cells. Mixed gas IG541, 8% of the 

carbon dioxide gas is artificially make the protection zone of rising carbon dioxide levels to 

meet the anoxic environment breathing for 2% 5%, and won't cause harm to human body.

 

1.1system structure 

unit independent system 

New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system

2.IG541 fire suppression system parts:

All parts made of IG541 system:stored bottle,driving gas bottle,bottle rack, connecting pipe,safety relief device, Low leakage and high sealing valve,one way valve,manifold pipe,gas check pipe,pressure switch,nozzle, colleting of sewage,flange,square bent, pressure reducing device

New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system

3.IG541 fire suppression system unique advantages:

 

1. Agent completely by nature exists in the atmosphere of inert gas, after the discharge to the 

environment completely without damage; 

2.Under prescribed fire extinguishing concentration is completely harmless to human body, can 

stay in one place safely use;

3. Fire extinguishing agent sources, can ensure long-term use;

4.Fire extinguishing agent is completely composed of inert gas, does not cause protection zone 

temperature fell sharply after discharge, the precision equipment and other valuable belongings 

without any harm;

5. Because of the storage pressure is higher, compared with other fire extinguishing system can 

transport a long distance, 

6.Under the combined distribution system methods can connect more protection zone, thus 

saving investment.

4.IG541 fire suppression system main technical parameters:

 

20 °C storage pressure: 15 MPa 

fire extinguishing agent storage bottles of specifications/filling quantity: 80l/16.8 Kg,

maximum working pressure (50 °C) : 17.2 MPa 1 start mode: magnetic start, mechanical 

emergency start 

electromagnetic drive air pressure: 6.0 + / - 1.0 MPa (20 °C) 

electromagnetic drive starting power: DC24V / 1.5 A 1.2.7 

agent application time: 60s or less

protection zone temperature: 0 °C to 50°C

store between bottle temperature: 0°C to 50°C

 

5.IG541 fire suppression system operation principle:

 

1. mixed gas IG541 automatic fire extinguishing system with automatic, manual, mechanical 

emergency operation three kinds of start ways. 

2.condition automatically, if a protection zone occurs with smoke (or temperature), the protection zone, smoke fire detector (or temperature) movement and the fire alarm controller into a single 

fire alarm, fire alarm controller that is into the single state, drive electric alarm signal of a single 

fire alarm at the same time, this time will not start the fire extinguishing system of control 

signals. As the spread of fire protection zone, the temperature rising smoke (or increase), the 

other primary circuit heat or smoke fire detector, the controller into a single fire signal, the 

controller immediately confirm that there is a fire, at the same time signal composite fire alarm 

and linkage (closed air conditioning, ventilation device and fire damper, fire doors, fire shutter, 

etc.). After 30 seconds of time delay, tThe controller output signal to start the fire extinguishing 

system, cast into the fire extinguishing agent through the pipeline to implement fire protection 

zone. Controller receives the feedback signal of pressure signal after the show bright deflated 

lights, avoid straying. In manual mode, alarm controller only when the fire broke out a fire alarm 

signals and does not produce linkage. 

3. requires automatic or manual mode, the personnel on duty after confirmation of fire, press the alarm controller on the front panel or the scene of the "emergency start" button to start the fire 

extinguishing system immediately. Before discharge control signal output, press the alarm 

controller on the front panel or the scene of the "emergency stop" button, the system will not 

discharge signal output.

Company Information

New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system New Concept Mixed Gas Fire Suppression System Accessories Ig541 Inergen Gas system

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More