Customization: | Available |
---|---|
Storage Pressure: | 2.5MPa or 4.2MPa |
Hfc-227ea Cylinder Capacity: | 100L |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HFC-227ea gas fire extinguishing system
1.HFC-227EA Gas fire extinguishing system introduction: |
HFC-227ea is a clean extinguishing agent, which would completely vaporized in the air, and well
insulated. Its total flooding mode is applicable to electric fire, liquid fire or fusible solid fire, solid
surface fire, gas fire which gas supply is cut before extinguishing. And it is able to protect computer rooms, communication rooms, substation rooms, hi-tech device rooms, generator rooms, gasoline storerooms, combustible chemical storerooms, libraries, data rooms, archives, treasuries, etc. We are manufacture HFC-227ea system that is well structured, reliable, and widely applied to computer rooms, archives, program control exchange engine rooms , TV broadcast center, financial organizations and government departments.
2.1 Storage of cylinder: 40L/70L/100L/120L/150L/180L
|
4.HFC-227ea system packing picture: |
Use wooden case packing,good protect,avoid breaking.
5.HFC-227ea Gas fire extinguishing system order instruction: |
HFC-227ea Fire Suppression system is one of Special Design and Manufacture products .
Before we make offer, we need your detailed information support to calculate the qty of Cylinder, weight of gas ,pipe size, nozzle ...
if the system you requested need design or not ?we design them free charges ,
We need following information to make design for your engineer projected
1>,What's your protected subject :
Telecommunication Facilities________Computer operations _______Control rooms __________
Shipboard (marine )system ________Rare book Libraries _________University and Museum?
Art Galleries _________________Petrochemical installations _________Medical Facilities and Pharmaceutical________
2>,do you have room 's layout or drawing
yes ( if yes please send us your attachment )
2. no (if no please tell us below protection status)
A room size : length(X width(m)X height ( m) (M)
B raise floor(can not greater than 30mm): _______(M ), or NO _____
C ceiling, height ____ (M) , or .no need consider
3>do you need a pressure release device ,yes .
4> storage cylinder must be placed in a separate room and towards the door opening direction
5> . HFC-227ea system select
A , Dependable system one system protect a single room(no need flow check valve)
B. Muliti-hazard system (One system protect multiple rooms(use selection valve)_________
6>.do you need fire alarm products ( control panel ,detectors , gas lamp ) yes no
7>.do you need pipe net yes no
8 >.do you need coupling and pipes yes . no
9>.do you need nozzle yes no
If nozzle requested please fill blew
Size: 1" 1.5" 2" 2.5"
Thread : Male or female
Nozzle holes number-------PCS ,holes diameter ____mm